The electric high-pressure cage type regulating valve adopts a cage type throttling form to distribute pressure difference, reducing cavitation, erosion, and flow damage, greatly improving the service life of the regulating valve, especially when used in urea systems, which is 2-3 times longer than ordinary high-pressure valves. The valve body is a straight through type, and the valve core is a single guide structure. The valve body has a simple flow path, low resistance, and is particularly suitable for regulating high viscosity fluids containing suspended solids and granular media, which can avoid coking, bonding, and blockage.
Item NO.:
XUVAL33-338Lead Time:
45 DaysProduct Orgin:
CHINABrand:
XUVALShipping Port:
ShanghaiPayment:
100%TTColor:
silvery1.Main technical parameters of valve body:
Valve body form | Straight through cast S-shaped valve |
Nominal Diameter | DN25~300mm |
Nominal pressure | PN11.0、PN15.0、PN26.0、PN42.0MPa;ANSI 150、300、600、900LB;JIS 10、20、30、40K |
Flange standard | GB/T9113、 JB/T79、HG20594And other standards |
Connection form | flange(FF RF RTJ)、weld(SW BW)、thread(refer to1″within) |
Valve cover form | Standard type-17~+250℃、High temperature type+250~+450℃、Low temperature type-60~-196℃、Bellows sealed type-40~+350℃ |
Gland type | Bolt compression type |
Packing | V-shaped PTFE filler, PTFE impregnated asbestos filler, asbestos textile filler, graphite filler |
Material | WCB,CF8、CF8M、CF3、CF3M)、Chromium molybdenum steel, cast steel with PTFE lining(WCB+F46) |
2. Valve trim:
Valve core form | Sleeve cage throttling valve core |
Flow characteristics | Linear, Equal Percentage |
Valve core material | stainless steel (304、304L、316、316L) |
3. Actuator:
Actuator model | 3810L series and imported actuators |
Main technical parameters | Power supply voltage: 220V/50Hz, input signal: 4-20mA or 1-5V · DC, output signal: 4-20mA · DC |
Protection level: equivalent to IP55, explosion-proof mark: Exd Ⅱ BT4 (special customizable CT6), manual operation function: handle | |
Environmental temperature: -25~+70 ℃, environmental humidity: ≤ 95% |
4、 Rated flow coefficient Kv and allowable pressure difference of electric high-pressure regulating valve:
Nominal Diameter DN | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
rated flow coefficientKV | straight line | 10 | 11 | 17.6 | 27.5 | 44 | 69 | 110 | 176 | 275 | 440 | 630 | 1000 | 1600 |
Equal percentage | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 155 | 250 | 370 | 580 | 900 | 1300 | |
Rated travel | 16 | 25 | 40 | 60 | 100 | |||||||||
Allowable pressure difference(Mpa) | ≤Nominal pressure |
If you are interested in our valves and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Tonglu Yongxin Valve Co.,Ltd.All Rights Reserved. Powered by dyyseo.com
IPv6 network supported