Power plant main steam gate valve
Product Introduction:
Product Name: Power Station Main Steam Gate Valve
Product model: Z961Y
Nominal diameter: NPS2 "~22"
Nominal pressure: Class1500~3500Lb
Drive mode: manual, gear transmission, electric
Applicable media: water, oil, steam
Design and manufacturing standard: ASME B16.34 E101
Structural length standard: ASME B16.34 E101
Welding connection dimensions: JB/T 3595-93, ASME B16.25
Pressure and temperature rating: ASME B16.34 E101
Test and inspection standard: API598 E101
Item NO.:
XUVAL-418
Lead Time:
45
Product Orgin:
China
Brand:
XUVAL
Shipping Port:
Shanghai
Payment:
100%
Color:
Silvery
MOQ:
1
Products Details
Application of Main Steam Gate Valves in Power Plants
The main steam gate valve of a power plant, also known as a special valve for power plants, is suitable for cutting off or connecting media on pipelines in various working conditions such as petroleum, chemical, and thermal power plants, with ANSI CLass 1500-3500 and operating temperatures ranging from -29 to 570 ℃. Applicable media include water, oil, steam, etc. The operating methods include manual, gear transmission, electric, etc.
Structural characteristics of main steam gate valves in power plants
1. The gate valve of the high-temperature and high-pressure power plant adopts an advanced equal diameter straight through structure, which greatly reduces the flow resistance coefficient and energy loss, and significantly improves the service life and performance of the valve.
2. The valve chamber adopts a pressure self tightening sealing structure with good sealing performance. The two ends of the branch pipe are welded structures.
3. The sealing surface of the gate and valve seat is made of Stellite cobalt based hard composite welding, which has good wear resistance, high temperature resistance, corrosion resistance, and scratch resistance.
4. The valve stem of the pound level high-temperature and high-pressure power plant gate valve has undergone quenching and surface nitriding treatment, which has good corrosion resistance and scratch resistance.
5. The structure of the opening and closing components can be designed in different forms such as single board, double board, parallel double board, etc. according to user requirements.
6. The opening and closing of electric gate valves are controlled by electric devices, which are equipped with dedicated motors, reducers, torque control mechanisms, on-site operation mechanisms, and manual and electric switching mechanisms. In addition to on-site operation, remote operation can also be carried out.
Send A Message
If you are interested in our valves and want to know more details,please leave a message here,we will reply you as soon as we can.