banner
Filter regulators
Home Filter regulators

Filter regulators

  • Introduction and Testing Principles of Y-type Filters
    • Jul , 11 2023
    Introduction and Testing Principles of Y-type Filters

    1. Introduction to Y-type Filter Y-type filters are an indispensable filtering device in pipeline systems that transport media. Y-type filters are usually installed at the inlet of pressure reducing valves, relief valves, constant water level valves, or other equipment to remove impurities from the media and protect the normal use of valves and equipment. The Y-type filter has the characteristics ...

  • The introduction of the main attachment of regulating valve
    • Jul , 24 2023
    The introduction of the main attachment of regulating valve

    Regulating valve positioner is a major attachment of pneumatic actuators, and pneumatic actuators, is used to improve the position precision of the valve, to overcome the friction of valve stem and medium the influence of unbalanced force, to ensure that the valve according to the regulator to signal to achieve the correct positioning. The following cases, to match the locator: 1 high and medium p...

  • Standard for the number of filter mesh for filters
    • Oct , 19 2023
    Standard for the number of filter mesh for filters

    First of all, we need to know what mesh size means: it refers to the particle size or thickness of the material, which is generally defined as within 1 inch × 1 inch (25.4mm × The number of mesh holes in an area of 25.4mm is defined as the number of mesh holes in the sieve, and the number of mesh holes that the material can pass through is defined as the number of mesh holes. This type of filter i...

  • Number of filter mesh for Y-shaped filter
    • Nov , 14 2023
    Number of filter mesh for Y-shaped filter

    1. The filter screen of the Y-type filter is generally made of stainless steel; 2. The general definition of filter mesh size refers to the number of mesh holes within an area of 1 inch * 1 inch (25.4mm), that is, the number of mesh holes in the screen; 3. The number of mesh used for general waterways is 8-30 mesh; 4. The filter mesh size of the chiller host is generally 16-20 mesh. Corresponding ...

  • Filter installation method and user manual
    • Nov , 16 2023
    Filter installation method and user manual

    1、 Filter principle Y-type filters are an indispensable filtering device in pipeline systems that transport fluid media. Y-type filters are usually installed at the inlet of pressure reducing valves, relief valves, shut-off valves (such as the inlet end of indoor heating pipelines) or other equipment to remove impurities in the medium and protect the normal use of valves and equipment. The Y-shape...

  • Working principle of Y-shaped filter
    • Feb , 27 2024
    Working principle of Y-shaped filter

    Y-shaped filters are an indispensable filtering device in pipeline systems for conveying media. Y-shaped filters are usually installed at the inlet of pressure reducing valves, relief valves, constant water level valves, or other equipment to remove impurities in the medium and protect the normal use of valves and equipment. The Y-shaped filter has the characteristics of advanced structure, low re...

  • Basic knowledge of pneumatic valve control accessories
    • Mar , 19 2024
    Basic knowledge of pneumatic valve control accessories

    Pneumatic valve is a type of valve driven by compressed air, which has the advantages of high efficiency, safety, and environmental protection, and is widely used in industrial automation control systems. Pneumatic valves consist of three parts: pneumatic actuator, control accessories, and valve body. The pneumatic actuator is the part that realizes the opening and closing action of the valve, whi...

  • Precautions for valve accessory selection - filter pressure reducing valve
    • Apr , 23 2024
    Precautions for valve accessory selection - filter pressure reducing valve

    The correct selection of valve accessories is of great significance for the reliable and stable operation of pneumatic valves. The control loop of the valve is composed of each accessory. Improper selection or failure of valve accessories can lead to abnormal or refusal of valve operation, posing a huge safety hazard to the process. The compressed air output from the air compressor contains a larg...

  • Common faults and handling methods of pneumatic valves
    • Apr , 30 2024
    Common faults and handling methods of pneumatic valves

    Pneumatic valves mainly refer to valves that are activated by cylinders to form a power source through compressed air, thereby achieving the purpose of regulating switches. When the regulating pipeline receives control signals generated from the automation control system, it will adjust relevant parameters (such as temperature, flow rate, pressure, etc.). Pneumatic valves are mainly composed of th...

    A total of

    1

    pages

Copyright © 2024 Tonglu Yongxin Valve Co.,Ltd.All Rights Reserved. Powered by dyyseo.com

IPv6 network supported

IPv6 network supported

top

Send A Message

Send A Message

    If you are interested in our valves and want to know more details,please leave a message here,we will reply you as soon as we can.